What Is Restricted Earth Fault Relay
What is restricted earth fault relay
Principle of restricted earth fault protection. The CT secondaries are wired to cancel each other's currents during through faults and to drive all secondary current to the relay when the fault is inside the protected zone. (Saturation of the CTs makes the situation a little more complicated than that.)
Why is restricted earth fault needed?
Because of this, the restricted earth fault (REF) element is often used to protect against ground faults in wye-connected windings. The location of current transformers (CTs) used in the scheme defines the zone of earth fault protection, which is why 'restricted' is included in the name of the element.
What is the difference between earth fault relay and restricted earth fault relay?
The earth fault relay must be very sensitive for sensing the fault. The relay is designed for sensing the fault current which is 15% more than that of the rated winding current. Such settings protect a restricted portion of the winding. Hence the name restricted earth fault protection.
Where is restricted earth fault used?
Restricted earth fault protection is provided in electrical power transformer for sensing internal earth fault of the transformer. In this scheme, the CT secondary of each phase of an electrical power transformer are connected together as shown in the figure.
What is meant by restricted earth?
Restricted Earth Fault (REF) means an earth fault from a restricted/localized zone of a circuit. The term "REF protection method " means not to sense any earth faults outside this restricted zone. This type of protection is prevalent in Dyn group of transformers (Delta Primary and Star Secondary).
What is SEF protection?
SEF Protection is required to detect high impedance faults which standard earth fault protection cannot detect. This ensures that situations where energised conductors which are on the ground can be detected and de-energised.
What is the difference between 50 and 51 relay?
50 and 51 are types of overcurrent relays (relays driven by a current transformer). Type 50 is an "instantaneous off" relay, whereas type 51 has an inbuilt time delay.
What is NCT in electrical?
Neutral Current Transformers (NCT) are common components in Electrical Distribution Systems.
Why Metrosil is used in ref protection?
Metrosils are used to limit the peak voltage developed by the current transformers under internal fault conditions, to a value below the insulation level of the current transformers, relay and interconnecting leads, which are normally able to withstand 3KV peak.
What is difference between ELR and EFR?
ELR means earth leakage relay or earth leakage circuit breaker, and EFR means earth fault relay. Both are protective relays. ELR will prevent shocks from circuit and protect life and EFR will protect transformers from fault current. Most of the EFR are IDMT type relays ie Inverse Definite Minimum Time.
What is the difference between earth leakage and earth fault?
Earth-fault current : current flowing to earth due to an insulation fault. Earth-leakage current : current flowing from the live parts to earth or extraneous conductive parts in the absence of an insulation fault.
What are the types of earth fault?
Basically there are just two type earth fault and restricted earth fault.
What is Nef protection?
NEF, probably : non directional earth fault protection.
What is the setting of earth fault relay?
The grading of the earth fault relay with a 630 A fuse requires a setting of at least 100%, or preferably 120%.
Why do we use neutral CT in a transformer?
A neutral current transformer is used as earth fault protection to measure any fault current flowing through the neutral line from the wye neutral point of a transformer.
What is difference between SEF & ref?
REF stands for restricted earth fault. SEF stands for standby earth fault.
How do you test sensitive earth fault?
The Sensitive Earth Fault protection scheme works by measuring the residual current across the three phases in a system. Measurement of three phase residual current is done either by using Core Balance Current Transformer (CBCT) or three CTs connected in parallel.
What is the difference between standby earth fault and sensitive earth fault?
In sensitive earth fault protection, one dedicated Core Balance CT is used to detect any unbalance in 3 phases and it's setting is so low so it's called sensitive earth fault protection. Where in Standby Earth fault protection, CT placed in neutral only and detect zero sequence current.
What is 50N and 51N?
ANSI 50N/51N: residual current calculated or measured by 3 phase current sensors. ANSI 50G/51G: residual current measured directly by a specific sensor.
How does a 50 51 relay work?
On electromechanical relays, the 50 function can be added as an instantaneous attachment to a 51 time-overcurrent relay. If a relay has both 50 and 51 functions present and enabled is referred to as a 50/51 relay. Typically, overcurrent relays are employed as one per phase.